Ideal Boiler Not Firing Up: Likely Reasons And How To Fix

If you find your Ideal boiler isn’t firing up, there could be any number of causes but fortunately, there are many checks you can do and fix yourself first, before needing an engineer.  However, if you don’t understand any of them it’s better to call a professional for safety reasons.

Ideal Boiler not firing up

If your Ideal boiler isn’t firing up, it could be due to low boiler pressure, a blocked jet, low thermostat, or other issues like faulty sensors. Check for blockages, adjust the thermostat, and try resetting a few times. If the problem persists, call an engineer for expert help.

If your Ideal boiler is not firing up,  a common reason might be a blocked jet. Take a close look for any dirty buildup, as you might be able to remove the blockage. Also, make sure there’s gas supply, and turn the dial down until you reach the reset light.

Ideal Boiler Pressure: Everything You Need To Know

The following causes relate to a combi boiler not firing up but most will also relate to other types of boilers such as system and heat only.

Ideal boiler not firing up

Main Causes for an Ideal boiler not firing up:

Faulty PCB

This is a common fault with these boilers so it has been mentioned first. If this goes faulty, which is usually shown by a flashing error light or code, the usual sequence of operation will abruptly stop and eventually, the boiler will go to lockout, not firing up at all. After resetting it a few times, you will most likely find you need an engineer to look into it.

No pilot light

The pilot light is a small constant gas flame that ignites your boiler. You can sometimes see it through the glass, mainly on older boilers. When your Ideal boiler won’t ignite and the pilot light has gone out, it is usually because the jet is blocked with debris. This requires a qualified engineer to clean. The boiler won’t ignite sometimes if the gas pressure is too low.

For old boilers that have pilot lights, check this is still on. You will need to get this on before the boiler ignites.  Modern combi boilers have automatic ignition so you won’t need to do anything manually.

Ideal Boiler Reviews: The Best Boilers for Your Home

Pilot light on but boiler not firing up

If you can see that the pilot light is on through the small window, but your Ideal boiler won’t fire, the cause could possibly be due to the boiler being low on pressure or losing pressure; the thermostat is not operational; the pump could be leaking or broken, or valves are closed not allowing water into the system.

Ideal boilers are fitted with various fail-safes that operate in certain conditions to prevent dangerous situations occurring or causing damage to the boiler. This is called a boiler lockout.

Wrong setting on room thermostat 

When coming out of the summer and the cold period starts, you may feel cold even at 21⁰ room temperature, but the thermostat may not have been touched for months.  So turn up the thermostat higher, say to 25⁰ C just to check the boiler fires up.

If the thermostat isn’t working, first check the batteries are in good working order and replace if necessary. Other than this, there might be a fault with the component inside or even faulty wiring.

Ideal Boiler Won’t Turn Off: Tips And Tricks

Boiler has no power going to it

This is one of the first checks to make.  Some things to check are:

Boiler fuse has blown

Following a power outage and the electricity coming back on, there is sometimes a surge of power. This can blow the fuse at the spur which means your boiler will have no power going to it and won’t fire up. Replace the fuse with a new one and the boiler should power up again.

Check the thermostat has power going to it

Are the batteries in the room thermostat still working? If the screen is dim, change the batteries.

The RCD has tripped

This causes a power issue to the boiler. The level or floor the boiler is located in could have lost power. Check the electrical consumer unit for tripped switches.

Have you got a pay as you go meter? 

This is just a reminder that the gas meter will need to be topped up with credit before any gas can come through to the boiler.  It’s an easy thing to overlook at the end of summer when you’ve not needed the heating on.

Ideal Combi Boiler Hot Water Goes Cold: What To Do

Low boiler pressure

The most common cause of an Ideal combi boiler not firing up is low boiler pressure.  A low reading on the gauge indicates system pressure loss which could be due a leak.  If the gauge is below 1 bar and especially close to zero, you will need to repressurise it to between 1.2 and 1.5 bar (check the user manual for the recommended level for your appliance).

Low gas pressure

The amount of gas being supplied to the boiler is too low. If the gas pipe to the combi boiler is not large enough, or other gas appliances such as a gas hob, cooker or gas fire are on at the same time and attached to that piece of pipework, the boiler does not get adequate gas to work properly. You will need to get a larger diameter gas pipe installed.

Radiators need bleeding

Trapped air in the radiators can also cause the boiler to not fire up.  Go round each radiator, starting with the top floor, and let any air out of them.  The pressure can go down after doing this so check you have the right level on the gauge.

Gas valve is blocked

If the gas valve on the boiler is blocked, you will be able to hear and even see the spark, but the burner will fail to ignite because there is no gas coming through. This is fairly common on Ideal boilers.

Blocked condensate pipe

The condensate pipe for a combi boiler can become blocked outside, especially in winter because of freezing conditions. As the condensate is discharged to an external drain, it can block the pipe in very cold weather which will cause the boiler to not fire. 

You can clear any blockage on the external pipe by pouring warm water over the pipe, or attaching a hot water bottle until the blockage is removed.

Check out our full guide to unblocking a frozen condensate pipe on the link below:

boiler repair

Common Ideal not firing up fault codes

  • L6: False flame lockout.
  • L9or F1 System water pressure is too low.
  • F2, FN or LN: Ignition lockout. A number of causes include blocked condensate pipe or flue.

Issues you will need to call a gas engineer for:

  • No pilot light.  Possibly blocked pilot injector unit
  • Stuck or faulty circulating pump
  • Incorrect gas pressures in the boiler
  • Fan issues within the boiler
  • Gas valve problems
  • Internal leaks causing pressure loss
  • An electrical fault within boiler

As you can see, there are many causes of an Ideal boiler not firing up, many of which you can check and fix yourself.  But when it comes to checking inside the boiler, be sure to get a qualified gas engineer.

If you’re looking for peace of mind that one call can take care of the home essentials, including all types of Ideal boilers, Hometree has great service at an affordable price.

Hometree offers customers peace of mind with home care packages for their boiler, central heating, plumbing, drains, and home electrics all at an affordable monthly or annual cost. Hometree’s aim is to take the stress out of boiler servicing and home maintenance with unlimited call-outs and a 24/7 helpline, as well as a no price-hike promise.

Click here to see why we recommend them for boiler cover.

Summary

The main causes of an ideal boiler not firing up are:

  • Wrong setting on the thermostat.
  • Boiler has no power going to it.
  • Low gas pressure.
  • Valves or pipes are blocked.
  • No pilot light.
  • Frozen condensate pipe.