Vaillant Boiler Not Firing Up: Common Causes and Solutions

If you find your Vaillant boiler isn’t firing up, there could be any number of causes but fortunately, there are many checks you can do and fix yourself first, before needing an engineer.  However, if you don’t understand any of them it’s better to call a professional for safety reasons.

Vaillant Boiler not firing up

If your Vaillant boiler is not firing up, the most common cause is low pressure. Or the thermostat has been set incorrectly. Check and fix these first and then reset the boiler. If the problem persists, it’s best to seek assistance from an engineer as other causes could be a blocked jet or a low gas supply. Damaged ignition leads or faulty sensors could also hinder the boiler’s firing.

Vaillant boiler not firing up

The following causes relate to a combi boiler not firing up but most will also relate to other types of boilers such as system and heat only.

Causes for a Vaillant boiler not firing up:

No pilot light

The pilot light is a small constant gas flame that ignites your boiler. You can sometimes see it through the glass, mainly on older boilers. When your Vaillant boiler won’t ignite and the pilot light has gone out, it is usually because the jet is blocked with debris. This requires a qualified engineer to clean. The boiler won’t ignite sometimes if the gas pressure is too low.

For old boilers that have pilot lights, check this is still on. You will need to get this on before the boiler ignites.  Modern combi boilers have automatic ignition so you won’t need to do anything manually.

Pilot light on but boiler not firing up

If you can see that the pilot light is on through the small window, but your Vaillant boiler won’t fire, the cause could possibly be due to the boiler being low on pressure or losing pressure; the thermostat is not operational; the pump could be leaking or broken, or valves are closed not allowing water into the system.

Vaillant boilers are fitted with various fail-safes that operate in certain conditions to prevent dangerous situations occurring or causing damage to the boiler. This is called a boiler lockout.

Why Does My Vaillant Boiler Keep Losing Pressure? Causes

Wrong setting on room thermostat 

When coming out of the summer and the cold period starts, you may feel cold even at 21⁰ room temperature, but the thermostat may not have been touched for months.  So turn up the thermostat higher, say to 25⁰ C just to check the boiler fires up.

If the thermostat isn’t working, first check the batteries are in good working order and replace if necessary. Other than this, there might be a fault with the component inside or even faulty wiring.

combi boiler not firing up image

Boiler has no power going to it

This is one of the first checks to make.  Some things to check are:

Boiler fuse has blown

Following a power outage and the electricity coming back on, there is sometimes a surge of power. This can blow the fuse at the spur which means your boiler will have no power going to it and won’t fire up. Replace the fuse with a new one and the boiler should power up again.

Check the thermostat has power going to it

Are the batteries in the room thermostat still working? If the screen is dim, change the batteries.

The RCD has tripped

This causes a power issue to the boiler. The level or floor the boiler is located in could have lost power. Check the electrical consumer unit for tripped switches.

Vaillant Boiler Won’t Turn Off: Common Problems And Fixes

Have you got a pay as you go meter? 

This is just a reminder that the gas meter will need to be topped up with credit before any gas can come through to the boiler.  It’s an easy thing to overlook at the end of summer when you’ve not needed the heating on.

Low boiler pressure

The most common cause of a Vaillant combi boiler not firing up is low boiler pressure.  A low reading on the gauge indicates system pressure loss which could be due a leak.  If the gauge is below 1 bar and especially close to zero, you will need to repressurise it to between 1.2 and 1.5 bar (check the user manual for the recommended level for your appliance).

Vaillant Boiler No Hot Water: Common Reasons And Fixes

Low gas pressure

The amount of gas being supplied to the boiler is too low. If the gas pipe to the combi boiler is not large enough, or other gas appliances such as a gas hob, cooker or gas fire are on at the same time and attached to that piece of pipework, the boiler does not get adequate gas to work properly. You will need to get a larger diameter gas pipe installed.

Radiators need bleeding

Trapped air in the radiators can also cause the boiler to not fire up.  Go round each radiator, starting with the top floor, and let any air out of them.  The pressure can go down after doing this so check you have the right level on the gauge.

Gas valve is blocked

If the gas valve on the boiler is blocked, you will be able to hear and even see the spark, but the burner will fail to ignite because there is no gas coming through. This is fairly common on Vaillant boilers.

Blocked condensate pipe

The condensate pipe for a combi boiler can become blocked outside, especially in winter because of freezing conditions. As the condensate is discharged to an external drain, it can block the pipe in very cold weather which will cause the boiler to not fire. 

Vaillant Combi Boiler Hot Water Goes Cold: Problems And Solutions

You can clear any blockage on the external pipe by pouring warm water over the pipe, or attaching a hot water bottle until the blockage is removed.

Check out our full guide to unblocking a frozen condensate pipe on the link below:

boiler repair

Common Vaillant not firing fault codes

  • F28: Start up failure boiler could not ignite or something failed during start up.
  • F29: Gas supply has been interrupted so the boiler could not ignite or reignite.
  • F54: Fault during boiler start up, there is insufficient gas pressure coming in.

Issues you will need to call a gas engineer for:

  • No pilot light.  Possibly blocked pilot injector unit
  • Stuck or faulty circulating pump
  • Incorrect gas pressures in the boiler
  • Fan issues within the boiler
  • Gas valve problems
  • Internal leaks causing pressure loss
  • Electrical fault within boiler

As you can see, there are many causes of a Vaillant boiler not firing up, many of which you can check and fix yourself.  But when it comes to checking inside the boiler, be sure to get a qualified gas engineer.

If you’re looking for peace of mind that one call can take care of the home essentials, including all types of Vaillant boilers, Hometree has great service at an affordable price.

Hometree offers customers peace of mind with home care packages for their boiler, central heating, plumbing, drains, and home electrics all at an affordable monthly or annual cost. Hometree’s aim is to take the stress out of boiler servicing and home maintenance with unlimited call-outs and a 24/7 helpline, as well as a no price-hike promise.

Click here to see why we recommend them for boiler cover.

Summary

The main causes of a Vaillant boiler not firing up are:

  • Wrong setting on the thermostat.
  • The boiler has no power going to it.
  • Low gas pressure.
  • Valves or pipes are blocked.
  • No pilot light.
  • Frozen condensate pipe.